NEMA Enclosure Types

2023-07-26 14:14:44 Young 80

NEMA MOTOR


Non-Hazardous Locations

Type 1 : General Purpose - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt.

Type 2 : Drip-Proof - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment, to provide a degree of protection against falling dirt, and to provide a degree of protection against dripping and light splashing of liquids.

Type 3 : Dusttight, Raintight, Sleettight - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and that will be undamaged by the external formation of ice on the enclosure.

Type 3R : Raintight, Sleet Resistant - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure.

Type 3S : Dusttight, Raintight, Sleettight - Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and in which the external mechanism(s) remain operable when ice laden.

Type 4 : Watertight, Dusttight, Sleet Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure.

Type 4X : Watertight, Dusttight, Corrosion-Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure.

Type 5 : Dusttight, Drip-Proof - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids.

Type 6 : Occasionally Submersible, Watertight, Sleet Resistant - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during occasional temporary submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure.

Type 6P : Watertight, Sleet Resistant Prolonged Submersion - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during prolonged submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure.

Type 12 : Dusttight and Driptight - Indoor

  • Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids.

Type 12K : Dusttight and Driptight, with Knockouts - Indoor

  • Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids.

Type 13 : Oiltight and Dusttight - Indoor

  • Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against the spraying, splashing, and seepage of water, oil, and noncorrosive coolants.

For enclosures used in

Hazardous Locations

Type 7 : Class I, Group A, B, C or D Hazardous Locations - Indoor

  • Enclosures constructed for indoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70.

Type 8 : Class I, Group A, B, C or D Hazardous Location - Indoor & Outdoor

  • Enclosures constructed for either indoor or outdoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70.

Type 9 : Class II, Group E, F or G Hazardous Locations - Indoor

  • Enclosures constructed for indoor use in hazardous locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA70.

Type 10 : Requirements of Mine Safety and Health Administration

  • Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18.

For more detailed and complete information, NEMA Standards Publication 250-2003, Enclosures for Electrical Equipment (1000 Volts Maximum) should be consulted.


Phone Number
Inquiry Form
E-Mail
主站蜘蛛池模板: 2021国产精品成人免费视频 | 爱爱视频免费网站 | 国产亚洲精品看片在线观看 | 一区二区三区不卡在线观看 | 国产亚洲欧美日韩国产片 | 欧美人与性动交α欧美精品 | 四虎国产一区 | 亚洲国产精品久久卡一 | 久久99国产精品视频 | 性欧美xxxxhd | a级毛毛片 | 久久综合九色综合欧洲色 | 一二三四视频社区5在线高清视频 | 一本色道 | 91精品福利 | 99久久精品免费 | 国产91久久精品一区二区 | 中文字幕在线观看亚洲日韩 | 久久伊人久久亚洲综合 | 日韩中文精品亚洲第三区 | a天堂影院 | 色噜噜狠狠色综合久 | 亚洲高清资源在线观看 | 欧美系列在线播放 | 大香焦伊人久久 | 网站免费视频高清免费 | 亚洲美女在线观看 | 四虎麻豆 | 中文字幕免费观看视频 | 免费在线看污 | 伊人网视频在线 | 一男一女一级毛片 | 在线播放一区二区精品产 | 伊人免费 | 色综合在| 久久成人永久免费播放 | 欧美线在线精品观看视频 | 欧美视频在线观 | 一级黄片一级毛片 | 3d动漫精品啪啪一区二区免费 | 亚洲精品午夜视频 |